Power and EVM TDSCDMA AL C

Code Sample Download

TD-SCDMA

Power and EVM
C Analysis Library

TDSCDMAANAC01 Power and EVM.zip

This example demonstrates the use of the TD-SCDMA Analysis Library
DLL interface in Microsoft Visual C++ V6.0 to perform the power and EVM
measurements:

  • Boot and configure digitizer
  • Create TD-SCDMA analysis library instance
  • Configure TD-SCDMAanalysis library
    • time slot to analyse
    • uplink switch point
    • slot time reference mode
    • sync mode
    • slot frequency reference mode
  • Capture and analyse a TD-SCDMA burst
    • Total Power
    • EVM RMS (Data)

    A siggen or a DUT will need to be generating RF bursts as follows:-

    • Frequency: 2GHz
    • time slot 3 is available
    • uplink switch point is 4
    • DwPts pilot is present

     

    It assumes that the following has been installed successfully:

    Hardware:
    =========
    Aeroflex 3011 RF Synthesizer PXI module
    Aeroflex 303x RF Digitizer PXI module

    Software:
    =========
    Aeroflex PXI Module Software - V6.6.0 or better
    Aeroflex TD-SCDMA Measurement Suite - v1.0.0 or better

    It is also assumed that:

    The 3010 LO output is connected to the 3030 LO input
    The 303x IF output is connected to the 303x IF input (if applicable)


    Disclaimer of Warranty

    This example code is provided 'as is' without warranty.

    Neither Aeroflex nor the author(s) warrant that the functions of the software will meet your requirements or that the media is compatible with any computer system on which it is used or that operation of the software will be unlimited or error free. You assume responsibility for selecting the software to achieve your intended results and for the installation of, the use of and the results obtained from the software. In no event shall Aeroflex or its suppliers be liable for any damages whatsoever arising out of installation of the software or incompatibility with any computer system or technical limitation of the software or use or inability to use the software, even if advised of the possibility of such damages. Neither Aeroflex nor the author(s) will be liable for any loss or damage of any nature suffered by any party as a result of reliance upon or reproduction of or any errors in any contents of the software.